Availability: | |
---|---|
Product Advantage | Product Parameters | ||
Biosafety Pass Box | VHP Pass Box | Biosafety Pass Box | VHP Pass Box |
1.UV disinfection on all sides | 1.High-density EPDM material. | 1.Air tightness test: The pressure test inside the chamber is 1500Pa, and there is no leakage. Equipment overall structure pressure test: 1500Pa, no leakage. | 1.Sealing: The initial positive and negative pressure test is 500pa, and after 20 minutes, the pressure should not be less than 250pa |
2.The four corners of the door leaf are designed with concentric circles. | 2.Built in VHP generator. | 2.Decontamination cycle time: < 120min | 2.Sterilization efficacy: can reduce the biological indicator of thermophilic Bacillus spores by 6 logarithmic units |
3.Adopting imported inflatable high-density sealing strips. | 3.Three sides of ultraviolet disinfection inside. | 3.Inflation pressure of 1.5KG/cm2, inflation time < 5 seconds, deflation time < 5 seconds, repeated more than 10000 times, no explosion or leakage phenomenon | 3.Pressure difference during sterilization: positive pressure ≤ 100Pa |
4.The four corners of the door leaf are designed with concentric circles. | 4.Configure imported VHP concentration probes. | 4.With built-in leakage alarm and fault alarm; | |
Self purification transfer window | 5.Noise: ≤ 75dB | ||
1.The box filter adopts AAF brand, the fan adopts EBM, and the overall filtering unit is used. | |||
2.The internal cavity of the electronic interlock adopts a circular arc design with no dead corners | |||
3.LCD screen control, electronic dual lock, dual pressure differential gauge. |
Product Advantage | Product Parameters | ||
Biosafety Pass Box | VHP Pass Box | Biosafety Pass Box | VHP Pass Box |
1.UV disinfection on all sides | 1.High-density EPDM material. | 1.Air tightness test: The pressure test inside the chamber is 1500Pa, and there is no leakage. Equipment overall structure pressure test: 1500Pa, no leakage. | 1.Sealing: The initial positive and negative pressure test is 500pa, and after 20 minutes, the pressure should not be less than 250pa |
2.The four corners of the door leaf are designed with concentric circles. | 2.Built in VHP generator. | 2.Decontamination cycle time: < 120min | 2.Sterilization efficacy: can reduce the biological indicator of thermophilic Bacillus spores by 6 logarithmic units |
3.Adopting imported inflatable high-density sealing strips. | 3.Three sides of ultraviolet disinfection inside. | 3.Inflation pressure of 1.5KG/cm2, inflation time < 5 seconds, deflation time < 5 seconds, repeated more than 10000 times, no explosion or leakage phenomenon | 3.Pressure difference during sterilization: positive pressure ≤ 100Pa |
4.The four corners of the door leaf are designed with concentric circles. | 4.Configure imported VHP concentration probes. | 4.With built-in leakage alarm and fault alarm; | |
Self purification transfer window | 5.Noise: ≤ 75dB | ||
1.The box filter adopts AAF brand, the fan adopts EBM, and the overall filtering unit is used. | |||
2.The internal cavity of the electronic interlock adopts a circular arc design with no dead corners | |||
3.LCD screen control, electronic dual lock, dual pressure differential gauge. |